Guide

Timber frame cutting list: from the framing to the pieces to cut

Published · Updated · 9 min read · By Tony Huaulmé

In short

A timber frame cutting list turns the framing into the pieces the saw must cut: for every piece, a mark, a section, a cut length and a quantity. List the pieces panel by panel, group identical lengths within each section, then place them on stock lengths to see the offcuts. The same data gives two views: by panel for the assembly table, by section and length for the saw. Check that the totals match the panel drawings and the wall take-off before you order.

The take-off tells you how much timber a wall needs. The cutting list tells the saw what to cut: which sections, in which lengths, how many, for which panel. The two must agree, and the cutting list is the one that decides how much timber goes in the skip. Here is how to build it from the framing, which columns it needs, how to group it, how to handle stock lengths, and a worked 8 m wall.

What is the difference between a cutting list, a parts list and a take-off?

The three come from the same data and answer different questions:

DocumentAnswersOrganised byUsed by
Parts list (nomenclature)What does this panel contain?Panel, then piece typeAssembly table, quality check
Cutting listWhat does the saw cut?Section, then lengthSaw, stock handling
Take-offHow much timber does the job need?Section, total length, volume, weightOrdering, transport, estimating

In practice the shop keeps one table of pieces, one row per piece type and panel, and builds the three views from it. The parts list is the panel's own part of the panel shop drawing. The wall take-off is the aggregate. The cutting list sits in between and decides what is actually bought and cut.

For steel, the equivalent step is described in light gauge steel take-off from a plan.

How do you get from the framing to a cutting list?

Start from the framing of each panel, as drawn on its sheet, and work through these steps:

  1. List the panels, with their marks, from the panel layout.
  2. List every piece in each panel: studs, jack studs, sills, short studs, bottom plates, top plates, lintels, noggings. Give each type a code (ST, JK, SL, SS, BP, TP, HB, LT). The head binder (HB), the second ply of the top plate, is listed separately, per wall: it is fitted on site, with its joints staggered from the panel joints.
  3. Give every piece its cut length, not the overall wall length: a stud is the wall height minus the plates, a bottom plate is cut at doors, a lintel is the opening plus its two bearings on the jack studs.
  4. Count the pieces of each length in each panel. Identical pieces share one row with a quantity.
  5. Add the section to each row. Never total different sections together: a 45 × 195 lintel isn't ordered like a 45 × 145 stud.
  6. Total each row (quantity × length) and each section.
  7. Place the lengths on stock lengths to see the offcuts and the real quantity to order (next sections).
  8. Check the totals against the panel drawings and the take-off.

Rebuilding the list by hand after every plan change is where lines get forgotten. Whichever tool you use, the list should be generated from the framing, not retyped.

What columns does a cutting list need?

ColumnContentWhy it is there
PanelPanel mark (W1-P1)Lets the pieces be kitted per panel
MarkPiece code (ST, JK, BP…)Matches the sheet and the label on the piece
PiecePlain name (stud, lintel)Readable at the saw
Section45 × 145, 45 × 195Sets the stock and the volume
QuantityNumber of identical piecesThe saw cuts them in one run
Cut length (m)Length of one pieceThe value the stop is set to
Total (m)Quantity × lengthCheck total and order quantity
NotesEnd cuts, treated timber, gradeAnything that changes how the piece is cut or bought

Keep lengths in the same unit as the saw's stop (metres to three decimals, or millimetres). A cutting list with mixed units is a cutting list with errors.

Should you group the list by panel or by section?

Both, from the same table. The two groupings serve different people:

GroupingGood forRisk if used alone
By panelKitting the pieces for one table, checking a panel against its sheetThe saw cuts the same length ten times in ten places, with more handling and more offcuts
By section, then lengthSawing in runs, sizing stock, nesting pieces on stock lengthsPieces lose their panel: you must label each piece with its mark as it is cut

The usual flow: sort by section and length for the saw, label each piece with its panel and mark, then deliver the pieces to the table kitted by panel. The label is what holds the two views together.

How do you handle stock lengths and offcuts?

Timber is bought in the lengths your supplier stocks, not in the lengths you need. The cutting list gives the pieces; nesting places them on stock lengths so that several pieces share one length and the offcut is as short as possible.

The rules of thumb:

Example: an 8 m wall in two panels, with its stock plan

Example

Wall W1 of 8.00 × 2.50 m, studs 45 × 145 at 600 mm centres, one bottom plate and a double top plate, lintels in 2 plies of 45 × 195, a window of 1.20 × 1.25 m (from 2.00 to 3.20 m, sill at 0.95 m) and a door of 0.90 × 2.20 m (from 5.55 to 6.45 m), as in the take-off guide. The wall is split into panels W1-P1 (0 to 4.20 m) and W1-P2 (4.20 to 8.00 m), the first ply of the top plate cut per panel. The second ply (the head binder) is fitted on site, with its joints at 3.00 and 6.00 m, staggered from the panel joint: it is listed separately, as wall binder pieces. Example values to show the method: replace them with those from your plan, your build-up and your supplier.

Cutting list of an 8 m timber frame wall in two panels: 79.575 lin. m of 45 × 145 and 4.56 lin. m of 45 × 195, 0.559 m³ of timber, about 235 kg
The cutting list of the example wall, by panel (illustration).

By panel. W1-P1 holds 9 studs, 2 jack studs, a sill, 2 short studs, a bottom plate, a top plate and 2 lintels (18 pieces). W1-P2 holds 10 studs, 2 jack studs, 2 bottom plate pieces (cut at the door), a top plate and 2 lintels (17 pieces). Wall binder pieces: the second ply of the top plate is 8.00 m long in 3 pieces (3.00, 3.00 and 2.00 m), butted at 3.00 and 6.00 m, that is 1.20 m and 1.80 m from the panel joint (4.20 m): it runs across the joint and ties the two panels together. The joint adds one end stud: 19 studs in all, against 18 in the continuous wall of the take-off guide.

By section and length (the saw's view), 45 × 145:

Cut length (m)QtyPiecesTotal (m)
2.36519Studs (both panels)44.935
2.1554Jack studs8.620
4.2002P1 bottom plate and top plate8.400
3.8001P2 top plate3.800
1.5501P2 bottom plate, door to corner1.550
1.3501P2 bottom plate, joint to door1.350
1.2001Window sill1.200
0.8602Short studs under the sill1.720
Total of the panels, 45 × 1453171.575
3.0002Wall binder: head binder, common pieces6.000
2.0001Wall binder: head binder, end piece2.000
Total 45 × 1453479.575
45 × 195: 1.290 × 2 and 0.990 × 24Lintels4.560

Volume and weight. 79.575 × 0.006525 + 4.56 × 0.008775 = 0.519 + 0.040 = 0.559 m³ net, about 235 kg in C24 at 420 kg/m³ (the density used in the take-off guide).

Stock plan. Suppose the supplier stocks 45 × 145 in 2.40, 3.00 and 4.20 m, and 45 × 195 in 2.40 m (example lengths: use your supplier's list):

StockLengthsPieces on each lengthOffcut (m)
45 × 145, 2.40 m231 stud (2.365) or 1 jack stud (2.155)0.035 or 0.245
45 × 145, 4.20 m32 plates of 4.20 exactly; 1 plate of 3.800 or 0.400
45 × 145, 3.00 m11.350 + 1.550 (bottom plate, P2)0.100
45 × 145, 3.00 m11.200 + 0.860 + 0.860 (sill and short studs)0.080
45 × 145, 3.00 m21 head binder of 3.00 exactly0
45 × 145, 2.40 m12.000 (head binder, end piece)0.400
45 × 195, 2.40 m21.290 + 0.990 (a window and a door lintel ply)0.120

To order: 82.20 m of 45 × 145 (31 lengths) and 4.80 m of 45 × 195 (2 lengths). The offcuts are 2.625 m on 45 × 145 (3.2 %) and 0.24 m on 45 × 195 (5 %). Add the shop's own allowance for defects and re-cuts on top. A different panel split, a higher wall or another stock list changes this plan, which is why the stock plan is redone for each job, not copied.

How do you check the cutting list before ordering?

Three controls, in this order:

  1. Per panel: the pieces of each panel on the list match the parts list of its sheet, line for line.
  2. Per wall: the totals by section equal the sum of the panels. A wall in panels exceeds the continuous wall by the end studs at the joints (one extra stud per joint in this example).
  3. Per job: the volume and weight by section match the take-off. A gap points to a missing line, a wrong cut length or a different build-up between the take-off and the drawings.

Do the check before the order goes out, not when the timber arrives short.

Frequently asked questions

What is a cutting list in timber frame construction?

The list of pieces the saw must cut, with for each one a section, a cut length, a quantity and a mark. It comes from the framing of each panel and is usually sorted by section and length.

What is the difference between a cutting list and a bill of materials?

The cutting list gives the pieces to cut from stock. A bill of materials (or parts list) gives everything that goes into a panel or a job, including boards, membranes and fixings. In a timber frame shop the cutting list covers timber and nothing else.

How do you reduce offcuts?

Match the piece lengths to the stock lengths: wall height and stud length against the stock, panel width against plate stock. Then nest short pieces on the remainder of long ones, and redo the plan when the wall height or the panel split changes.

Should the cutting list include noggings?

Yes, if your build-up has them. Add a line per row of noggings in each panel, with its section and cut length. The example above has none, so its totals stay comparable with the take-off guide.

Doing it with Stud: the quantities to check the list against

Stud is an AI agent, in free beta, that builds the model, the panels and the framing from the plan you already have, and gives the quantities:

  • you upload a DXF or PDF plan, a plan image or a dimensioned sketch; the agent builds the 3D model and uses a standard value, flagged for you, for a dimension it is missing;
  • it splits the walls into panels with the maximum width and stud spacing you set, and draws the framing of each panel, step by step in the 3D view;
  • the take-off gives the wall, floor and roof surfaces, and the volume and weight of timber, from the model; when the plan changes, you ask for the change and the quantities follow;
  • with the Framer plan, the production PDFs give the framing plan of each level and one sheet per panel.

The timber volume and weight are your control total: your cutting list, grouped however the saw needs it, must come back to them. Stud doesn't draw up the cutting list for you, and it doesn't do structural design or code checks. The free beta does everything in the app, without exports.

Try the beta for free

Free beta: sign up and try it on one of your own plans, then compare the timber weight with your list.